Skip to main content

EcoSystem 50 Functional

Technical information

Performance

Comfort

Air tightness
Class 2 (300Pa)
Water tightness
Class 4A (150Pa)
Wind load resistance
Class C2 (800Pa)
Acoustics - Rw(C;Ctr)
40(-2;-4) dB
Opening & closing resistance
Class 6 (200000 cycles)

Safety

Burglar resistance
RC2 - PAS 24
Impact resistance
I5 - E5
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
700 mm
Min. width of vent
500 mm

Sightlines

Min. frame width (inward opening)
67 mm
Min. vent width (inward opening)
74 mm
Min. frame-vent width (inward opening)
141 mm
Min. frame width (outward opening)
42 mm
Min. vent width (outward opening)
99 mm
Min. frame-vent width (outward opening)
141 mm
Min. width T-profile
70 mm
Min. height treshold
0 mm
Depth frame
50 mm
Depth Vent
50 mm
Depth frame-vent
50 mm

Glazing

Rebate height
22 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
Min. glass thickness - frame/element
4 mm
Max. glass thickness - frame/element
32 mm