ConceptWall 86
Technical informationPerformance
Energy
- Thermal insulation - Uf
- 1.9 W/m²K
Comfort
- Air tightness
- 0.04 cfm/ft³
- Water tightness
- 9 psf
- Air tightness
- AE 900 (900Pa)
- Water tightness
- RE1200 (1200 Pa)
- Wind load resistance
- Class B5 (2000Pa)
- Acoustics - Rw(C;Ctr)
- 41(-2;-6) dB
Safety
- Burglar resistance
- RC2
- Impact resistance
- I5 - E5
Properties
Max. dimensions & weight
- Min. height of vent
- 500 mm
- Max. height of vent
- 2000 mm
- Min. width of vent
- 500 mm
- Max. width of vent
- 2000 mm
- Max. weight of vent
- 180 kg
- Max. weight of glass
- 300 kg
- Min. intertia mullion - Ix
- 13.85 cm4
- Max. intertia mullion - Ix
- 544.25 cm4
- Min. intertia transom - Ix
- 38.86 cm4
- Max. intertia transom - Ix
- 435.83 cm4
- Min. intertia transom - Iy (glass load)
- 51.54 cm4
- Max. intertia transom - Iy (glass load)
- 153.38 cm4
Sightlines
- Min. width T-profile
- 86 mm
- Min. visible width (interior view)
- 86 mm
- Min. visible width (exterior view)
- 86 mm
- Min. depth mullion
- 6.5 mm
- Max. depth mullion
- 120 mm
- Min. depth transom
- 26.8 mm
- Max. depth transom
- 144.5 mm
Glazing
- Glazing method
- Dry glazing - External glazing - Glazing bead - Structural Glued Glazing
- Min. glass thickness - frame/element
- 6 mm
- Max. glass thickness - frame/element
- 38 mm
- Min. glass thickness - vent
- 6 mm
- Max. glass thickness - vent
- 38 mm